2026-10-07 · Water Heater Vista
Troubleshooting No Hot Water After a Power Outage in LA
If you have no hot water after a power outage, check three things first: the water heater's breaker (electric), the pilot or ignition (gas), and the high-limit reset button. Many gas tanks with a standing pilot are not affected by a power outage at all, so if yours is, look for a different cause. Stop and call a professional if you smell gas or a breaker keeps tripping.
First, identify your heater
- Electric tank: a dedicated double-pole breaker in your panel, no flame or vent.
- Standing-pilot gas tank: a pilot flame visible through a small window, no power needed to run.
- Electronic-ignition gas tank or tankless: needs power for ignition and controls, so outages and surges can interrupt it.
Electric heaters
- Find the heater's breaker. If it is tripped or in the middle position, switch it fully off, then on.
- If the breaker trips again right away, stop. See our electric water heater not heating guide.
- Turn the breaker off, remove the upper access panel, and press the red high-limit reset button.
- Restore power and allow time for the tank to reheat. Recovery time depends on tank size and element wattage, so check your manual.
Gas heaters
If the pilot has gone out, relight it following the label on the heater. Hold the button for the time the instructions say so the thermocouple can heat. If it will not stay lit, or you smell gas, stop and call a pro. Our pilot light service page explains common causes. Electronic-ignition models may need you to cycle power or check a status light; consult the manual for the blink code.
Tankless heaters
Tankless units need power for ignition, fans and sensors. After an outage, check that they have power, the display is on, and any error code is noted. Persistent codes after power returns can mean a fault that needs service; see our tankless troubleshooting guide.
Quick table
| Heater type | Does an outage affect it? | First check | |---|---|---| | Electric tank | Yes, and surges can trip the breaker | Breaker, reset button | | Standing-pilot gas | Usually no | Pilot, gas valve | | Electronic-ignition gas | Yes | Power, status light | | Tankless | Yes | Power, error code |
Do not do these
Do not keep resetting a breaker that trips, bypass the high-limit switch, or relight a pilot if you smell gas. Do not power an electric heater unless the tank is full of water.
When to call a pro
Call a technician if the breaker keeps tripping, the pilot will not stay lit, you see error codes after power returns, or there is no hot water after you have completed the checks. Our no hot water page covers other causes. Residents of Atwater Village and nearby can request a callback from the contact page and ask for the diagnosis and price before work begins.